Difficulty

Moderate

Steps

4

Time Required

                          4 - 5 minutes            

Sections

2

  • Disassembly
  • 2 steps
  • Fingerprint
  • 2 steps

Flags

1

Action Shots

Be an action hero! This guide needs images that better demonstrate how to perform specific actions.

  • BackuAttend bn6000

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              Disassembly               
  • Make sure to unplug the device before starting.
  • Flip the device over.
  • Remove the four 10mm PH #2 screws by rotating the screwdriver counterclockwise, removing the screw from the housing completely.

Make sure to unplug the device before starting.

Flip the device over.

Remove the four 10mm PH #2 screws by rotating the screwdriver counterclockwise, removing the screw from the housing completely.

1024

Step 2

  • Separate the two cover pieces carefully by pulling apart the two cover pieces away from each other.

Separate the two cover pieces carefully by pulling apart the two cover pieces away from each other.

Step 3

              Fingerprint               
  • Remove the two 7mm PH #1 screws from the fingerprint scanner mounting tab by rotating the screw driver counter clockwise, removing the screw from the housing completely.
  • Remove the fingerprint scanner assembly from the unit by lifting the scanner up and away from the unit housing.

Remove the two 7mm PH #1 screws from the fingerprint scanner mounting tab by rotating the screw driver counter clockwise, removing the screw from the housing completely.

Remove the fingerprint scanner assembly from the unit by lifting the scanner up and away from the unit housing.

Step 4

  • Disconnect the ZIF connector, by using your fingernail to lift up on the small locking flap. Then pull the ribbon up and away, out of the connector.

Disconnect the ZIF connector, by using your fingernail to lift up on the small locking flap. Then pull the ribbon up and away, out of the connector.

To reassemble , follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      One other person completed this guide.                                             

Author

                                      with 2 other contributors 

                    abdullah sumait                     

Member since: 09/20/2017

419 Reputation

                                      4 Guides authored                  



                       Badges:
                       10







                                                        +7 more badges                           

Team

                       Idaho State University, Team S4-G1, Watkins Fall 2017                        

                                                  Member of Idaho State University, Team S4-G1, Watkins Fall 2017 



                    ISU-WATKINS-F17S4G1                     


                                            3 Members                     


                                            5 Guides authored